ChaseWall Partition

ChaseWall Partition Clean, Secure Separation of Equipment Corridors from the Data Hall A Cost-Effective Alternative to Drywall Partitions Attributes: The Gordon ChaseWall is a demountable partition, providing a clean, secure barrier between equipment corridors and the data hall. ChaseWall is a non-progressive design, engineered to be easily assembled from only one side, with the head track attaching directly to the Gordon DG 1.5/1.5M/3.0/3.0M/X-SPAN ceiling grid. In addition to being durable and structurally sound, the installed cost of ChaseWall is comparable to a finished gypsum board wall, but without the contamination associated with taping, floating, sanding, and painting inside the white space. • Modular, in standard 4’ (nominal) width panels to match grid array • Light in weight, easily handled components • Engineered for rapid installation...8-10 times faster than drywall construction! • Demountable; in sections for equipment move-in, or in full for partition relocation • Non-progressive, allowing for removal of 1 or more wall panels from any location along the wall structure, thus facilitating equipment move in or relocation • Adaptable design to allow for multiple panel types (Structural polycarbonate, metal face over honeycomb-core or composite, solid polycarbonate). Standard panels are 16mm (5/8”) thick. • Class A rated components for flame spread/smoke generation • Extruded aluminum wall components • Finish: aluminum extrusions are etched and Clear Anodized, panels in “Ice” White

GORDON DATA CENTER WALLS 2 ChaseWall Details Side View Top View PARTITION WALL HEIGHT 14'-0" [168.000"] MAX PARTITION WALL LENGTH 4'-0" [48.000"] POST CL WALL TERMINATION DISTANCE VARIES (49.500" MAX) CEILING HEIGHT FINISHED FLOOR DW-PANEL J-TRIM DW-TOP RAIL FASCIA DW-TOP RAIL DW-POST CAP WITH DW-POST BEHIND DW-TOP RAIL FILLER EXISTING DEMISING WALL EXISTING DEMISING WALL DW-PANEL INSTALLATION START POINT 4'-0" [48.000"] DW-POST CL WALL TERMINATION DISTANCE VARIES (49.500" MAX) DW-POST DW-FLOOR BRACKET DW-PANEL J-TRIM (BELOW) FIELD INSTALLED AT BOTTOM OF PANELS DW-POST CAP USE GUIDELINE NOTCHES IN DW-FLOOR BRACKET FOR INSTALLATION ALIGNMENT CLOF DW- POST & DW-FLOOR BRACKET CL FIELD ATTACH NEOPRENE BLACK GASKET SPACERS WITH DOUBLE SIDED TAPE DW-PANEL CL DW-TOP RAIL SLOTTED 12" OC TO CONNECT WITH CEILING GRID PLAN VIEW AT FLOOR PLAN VIEW AT CEILING 3'-9" [45.000"] POST ID

3 GORDON DATA CENTER WALLS Floor Detail Ceiling Detail DW-POST CAP DW-FLOOR BRACKET DW-PANEL J-TRIM (FIELD INSTALLED) DW-POST DW-PANEL USE GUIDELINE NOTCHES IN FLOOR BRACKET FOR INSTALLATION ALIGNMENT DG 1.5 CEILING GRID DW-TOP RAIL 1/4-20 X 3/8" BOLT (2X) PER TOP BRACKET DW-TOP BRACKET (2X) PER POST SECURE DW-TOP RAIL TO CEILING GRID USING 3/8-16 X 1/2" HEX BOLT SNAP DW-POST CAP INTO DW-POST DW-TOP RAIL FASCIA DW-TOP RAIL DW-TOP RAIL FASCIA DW-TOP RAIL FILLER DW-PANEL DW-TOP RAIL FILLER

CW010 10/22 5023 HAZEL JONES ROAD, BOSSIER CIT Y, LA 71111 800.747.8954 800.877.8746 FAX SALES@GORDON-INC.COM GORDON-INC.COM AN EMPLOYEE OWNED COMPANY

RkJQdWJsaXNoZXIy NDExNjIx