Gasketed Grids

GASKETED GRIDS CANTRELL DRUG Little Rock, AR GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

CG SYSTEM T E C HN I C A L I N F O R M A T I O N 5023 HAZEL JONES ROAD, BOSSIER CI T Y, L A 71111 2 Applications for CG systems include food service, food processing, pharmaceutical, and hospital industries. Designed with a 1-1/2" face tee to support HEPA filter systems, CG systems are also available in other sizes such as 15/16" and 2". Installation is simplified with a clip assembly requiring no special tools for the attachment of grid components. Choose from a wide selection of module sizes such as 2' x 2', 2' x 4', or 4' x 4'. Gordon can also supply any custom module size required. CG systems are available in powder coat white and clear anodized finish. C G PA R T S C G A C C E S S O R I E S FACTORY APPLIED GASKETS: The standard CG series gasketing is a flexible closed cell polyethylene foam which is crosslinked by means of a unique electron irradiation process. GASKET SIZE CG-10 - 3/32” x 3/8” CG-15 - 3/32” x 15/32” CG-20 - 3/32” x 23/32” CUSTOM GASKETS Gaskets are available with adhesive on one or both sides in polyvinyl, neoprene, polyethylene, anti-bacterial, and flame retardant. Call Gordon if custom gaskets are required. GASKET SPECIFICATIONS Gasketing is off white in color, excellent chemical resistance, and has a 2# density per cubic foot. • Passes fungus resistance test (Method 508.1 mill-std-810C) • Flame-resistant (FMYSS #302 with burn rate of 4” per minute) • Shore Hardness (ASTM D-2240) on AA scale is 7; on OO scale is 51, 2# density per cubic foot. FINISHES • Clear satin anodized aluminum for harsh environments. • Pearl White Antimicrobial powder coating • Custom finishes. GRID LAYOUT MODULES • 2’ x 4’ • 2’ x 2’ • Metric or custom module sizes can be provided. LIGHT FIXTURE COMPATIBILITY CG systems require fixtures designed specifically for cleanroom applications. PART NUMBER A-WEB B- EXPOSED LENGTH WEIGHT PER LINEAR FOOT/W GASKET PIECES PER CARTON WITH GASKET LINEAR FEET PER CG-10-MT Main Tee 1-1/2" 15/16" 12' 0.18 40 480 CG-15-MT Main Tee 1-1/2" 1-1/2" 12' 0.24 24 288 CG-20-MT Main Tee 2" 2" 12' 0.31 16 192 CG-10-48 Cross Tee 1-1/2" 15/16" 4' 0.18 120 480 CG-10-24 Cross Tee 1-1/2" 15/16" 2' 0.18 120 240 CG-15-48 Cross Tee 1-1/2" 1-1/2" 4' 0.24 72 288 CG-15-24 Cross Tee 1-1/2" 1-1/2" 2' 0.24 72 144 CG-20-48 Cross Tee 2" 2" 4' 0.31 48 192 CG-20-24 Cross Tee 2" 2" 2' 0.31 48 96 CG-WA-1 Wall Angle 3/4" 3/4" 12' 0.09 40 480 CG-WA-2 Wall Angle 15/16" 15/16" 12' 0.12 40 480 CG-WA-4 Wall Angle 1-1/2" 15/16" 12' 0.16 30 360 CG-WA-4S Wall Angle 15/16" 1-1/2" 12' 0.16 30 360 CG-WA10G Wall Angle 1-1/2" 15/16" 12' 0.19 30 360 CG-WA-15 Wall Angle 1-1/2" 1-1/2" 12' 0.22 30 360 CG-WA-20 Wall Angle 2" 2" 12' 0.3 30 360 MTS Main Tee Splice One Per Main Tee CG-2Way 2 Way Clips One per CG Cross Tee CGHC Steel Hold Down Clips As needed for panel security/usually 4 per module 90 ACA 90˚ Angle Clip Tee attachment to wall angle A B GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

5023 HAZEL JONES ROAD, BOSSIER CI T Y, L A 71111 3 L O A D D A T A S T A ND A R D MO DU L E S C G - T E C H N I C A L S P E C I F I C A T I O N S Load test recommendations outlined in the table at right should not be exceeded, nor should the components be deflected more than 1/360th of their span. A minimum 12 gauge hanger wire should support all four corners of the filter unit or light fixture. SYSTEM TYPE WEB HEIGHT SPAN HANGER WIRE SPACING SPACING OF MAIN TEES APPLIED LOAD LBS./ SQ.FT. ASTM CG-20 2" 48" 48" 24" 48" 10.2 5.1 Heavy Duty Heavy Duty CG-15 1-1/2" 24" 42" 48" 48" 48" 48" 14.7 4.8 2.6 Heavy Duty Heavy Duty Light Duty CG-10 1-1/2" 42" 48" 48" 48" 24" 48" 4.8 4.5 2.2 Heavy Duty Light Duty Light Duty CG-10 24” x 48”MODULE CG-15 24” x 48”MODULE CG-20 24” x 48”MODULE Note: Standard 2' x 4' lay-in light fixtures are not compatible with the CG-15, and CG-20 systems PART 1: GENERAL 1.1 INTRODUCTION Furnish and install Gordon extruded aluminum grid ceiling systems as manufactured by Gordon, Inc. All material and workmanship shall be of the highest quality; assembly and installation shall be in accordance with Gordon detailed instructions and specifications. 1.2 DESCRIPTION OF SYSTEM 1.2.1. The Gordon extruded aluminum grid system is an integrated ceiling which has the flexibility of including architectural components, mechanical air handling (supply or return) and lighting fixtures. Designer to select components required and edit this specification to suit job requirements. PART 2: PRODUCTS 2.1 ARCHITECTURAL COMPONENTS The 24” x 48” modular Gordon framing members shall be extruded aluminum alloy 6063-T5. Exposed surfaces shall have a (clear anodized) (Pearl White Antimicrobial powder coat) finish. 2.2 Gordon Extruded Aluminum Grid Components shall be CG-(10) (15) (20) Series. The 24” Modular Ceiling Suspension System shall be Gordon, Inc. CG-(10) (15) (20) consisting of a 12’-0” Main Tee, and 4’ and/or 2’ nominal cross Tees, manufactured of extruded aluminum components by Gordon, Inc. All members shall be of standard 6063 T-5 aluminum alloy. Each Cross Tee shall be factory fabricated for independent aluminum bend-tab clips on each end. 2.3 Main runners shall be joined together at each end by means of an independent aluminum bend-tab splice member. 2.4 Cross members shall attach to main runners and other cross runners by means of an independent aluminum bend-tab clip which penetrates and slides through slots in main runners and other cross runners. 2.5 All grid components of the system shall have factory applied Polyethylene Gasket with adhesive one side. 2.6 The framing shall comply with ASTM C-635 “Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings”, with (heavy duty) (light duty) designation. PART 3: LIGHTING (optional) PART 4: AIR DIFFUSION (optional) PART 4: ACCESSORIES 5.1 Wall angle to be 12’-0” long of extruded aluminum, alloy 6063-T5 and shall be finished to match Gordon extruded grid. PART 6: INSTALLATION 6.1 Gordon CG-(10) (15) (20) Series Grid shall be installed in accordance with ASTM C-636, “Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Ceilings.” 6.2 Acoustical panels shall be installed in accordance with the acoustical panel manufacturer’s recommendations. 6.3 Light fixtures, and/or light fixture support frames shall be installed in framing by appropriate trade at locations as designated on the reflected ceiling and electrical plans. Wiring shall be by electrical contractor. 6.4 Air supply and return components shall be installed in framing by appropriate trade at locations as designated on the reflected ceiling and mechanical plans. 6.5 Hanger wire to be 12 gauge with appropriate attachment devices for overhead structure. GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

CG SYSTEM C OMP O N E N T S & A C C E S S O R I E S 5023 HAZEL JONES ROAD, BOSSIER CI T Y, L A 71111 4 GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

5023 HAZEL JONES ROAD, BOSSIER CI T Y, L A 71111 5 RG SYSTEM T E C H N I C A L I N F O R M A T I O N Applications for RG systems include the pharmaceutical, food processing, and hospital industries. The RG system differs from the CG system in that the 1-1/2" extruded aluminum face tee is designed with an 1/4" upturned flange that closes the gap caused by the gasket between panels, light fixtures, and tee flange and provides a sharp architectural detail. Panels or filters contact the gasket first to complete a seal prior to settling on the tee flange. The RG upturned flange also provides a caulkable surface. R G PA R T S R G A C C E S S O R I E S FACTORY APPLIED GASKETS: RG Series gasketing: The standard RG-15 series gasket is 1/4” x 1/2” closed cell PVC, gray in color, with small cells and a smooth surface. GASKET SIZE RG-15 - 1/4” x 1/2” CUSTOM GASKETS Gaskets are available with adhesive on one or both sides in polyvinyl, neoprene, polyethylene, anti-bacterial, and f lame retardant. Call Gordon if custom gaskets are required. GASKET SPECIFICATIONS • Passes fungus resistance test (Method 508.1 mill-std-810C) • Flame-resistant (FMYSS #302) with burn rate of 4" per minute • Shore Hardness (ASTM D-2240) on AA scale is 7; on OO scale is 51 • 8# density per cubic foot • U.S.D.A. approved. FINISHES • Clear satin anodized aluminum for harsh environments. • Pearl White Antimicrobial powder coat. • Custom finishes. GRID LAYOUT MODULES • 2’ x 4’ • 2’ x 2’ • Metric or custom module sizes can be provided. LIGHT FIXTURE COMPATIBILITY RG systems require fixtures designed specifically for cleanroom applications. PART NUMBER DESCRIPTION A-WEB B- EXPOSED LENGTH WEIGHT PER LINEAR FOOT/W GASKET PIECES PER LINEAR FEET PER RG-15-MT4 4' Notch Main Tee 1-3/4" 1-1/2" 12' 0.31 16 192 RG-15-MT2 2' Notch Main Tee 1-3/4" 1-1/2" 12' 0.31 16 192 RG-15-48CN Cross Tee Center Notch 1-3/4" 1-1/2" 4' 0.31 48 192 RG-15-48NN Cross Tee No Notch 1-3/4" 1-1/2" 4' 0.31 48 192 RG-1548HN Cross Tee Half Notch 1-3/4" 1-1/2" 4' 0.31 48 192 RG-15-24 Cross Tee 1-3/4" 1-1/2" 2' 0.31 48 96 RG-WA-48 4' Notch Wall Angle 1-1/2" 3/4" 12' 0.23 24 288 RG-WA-24 2' Notch Wall Angle 1-1/2" 3/4" 12' 0.23 24 288 MTS Main Tee Splice One per main tee RG-2 Way Clips 2 Way Clips One per cross tee RGHC Hold Down Clips As needed for panel security/usually 4 per module 90 ACA 90˚ Angle Clip Tee attachment to wall angle RGHGR Sliding Hanger Clip Optional hanger clip slides along web of the tee allowing hanger wire attachment when special clearances for filters or fixtures are required A B GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

RG SYSTEM 5023 HAZEL JONES ROAD, BOSSIER CI T Y, L A 71111 6 L O A D D A T A M E T A L PA N E L S R G - T E C H N I C A L S P E C I F I C A T I O N S Load test recommendations outlined in the table should not be exceeded, nor should components be deflected more than 1/360th of their span. A minimum 12 gauge hanger wire should support all four corners of the filter unit or light fixture. SYSTEM TYPE WEB HEIGHT SPAN HANGER WIRE SPACING SPACING OF MAIN TEES APPLIED LOAD LBS./ SQ.FT. ASTM C-635 RG-15 1-3/4" 48" 24" 48" 8.9 4.4 Heavy Duty Heavy Duty PART 1: GENERAL 1.1 INTRODUCTION Furnish and install Gordon extruded aluminum grid ceiling systems as manufactured by Gordon, Inc. All material and workmanship shall be of the highest quality; assembly and installation shall be in accordance with Gordon detailed instructions and specifications. 1.2 DESCRIPTION OF SYSTEM 1.2.1. The Gordon extruded aluminum grid system is an integrated ceiling which has the flexibility of including architectural components, mechanical air handling (supply or return); and lighting fixtures. Designer to select components required and edit this specification to suit job requirements. PART 2: PRODUCTS 2.1 ARCHITECTURAL COMPONENTS The 24” x 48” modular Gordon framing members shall be extruded aluminum alloy 6063-T5. Exposed surfaces shall have a (clear anodized) (Pearl White Antimicrobial powder coat) finish. 2.2 Gordon Extruded Aluminum Grid Components shall be RG-15 Series. The 24” Modular Ceiling Suspension System shall be Gordon, Inc. RG-15 consisting of a 12’-0” Main Tee, and 4’ and/or 2’ nominal Cross Tees, manufactured of extruded aluminum components by Gordon, Inc. All members shall be of standard 6063 T-5 aluminum alloy. Each Cross Tee shall be factory fabricated for independent aluminum bend-tab clips on each end. 2.3 Main runners shall be joined together at each end by means of an independent aluminum bend-tab splice member. 2.4 Cross members shall attach to main runners and other cross runners by means of an independent aluminum bend-tab clip which penetrates and slides through slots in main runners and other cross runners. 2.5 All grid components of the system shall have factory applied 1/4” x 1/2” PVC gasket with adhesive one side. 2.6 The framing shall comply with ASTM C-635 “Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings”, with heavy duty designation. PART 3: LIGHTING (optional) PART 4: AIR DIFFUSION (optional) PART 5: ACCESSORIES 5.1 Wall angle to be RGWA-15, 12’-0” long of extruded aluminum, alloy 6063-T5 and shall be finished to match Gordon extruded grid. PART 6: INSTALLATION 6.1 Gordon RG-15 Series Grid shall be installed in accordance with ASTM C-636, “Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Ceilings.” 6.2 Acoustical panels shall be installed in accordance with the acoustical panel manufacturer’s recommendations. 6.3 Light fixtures, and/or light fixture support frames shall be installed in framing by appropriate trade at locations as designated on the reflected ceiling and electrical plans. Wiring shall be by electrical contractor. 6.4 Air supply and return components shall be installed in framing by appropriate trade at locations as designated on the reflected ceiling and mechanical plans 6.5 Hanger wire to be 12 gauge with appropriate attachment devices for overhead structure. Custom .032" aluminum panels are manufactured in all sizes to allow for non-standard module sizes, fill-in perimeter panels, and sprinkler panels. Note: Standard 2' x 4' lay-in light fixtures are not compatible with the RG-15 system GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

5023 HAZEL JONES ROAD, BOSSIER CI T Y, L A 71111 7 C OMP O N E N T S & A C C E S S O R I E S 90° ANGLE CLIP HANGER WIRE (BY OTHERS) 1 3/4" 1-1/2" 1/4" 1-1/2" 5/16" 3/4" FIELD CUT GASKET BACK ON ONE SIDE TO CREATE GASKET OVERLAP MTS MAIN TEE SPLICE CLIP BEND TABS TOWARDS SPLICE LOCATIONS, TYP RG HANGER CLIP CROSS TEE ENDS FACTORY BACK-CUT AND COPED FOR FACE ALIGNMENT AND EXTRA SYSTEM STRENGTH BEND DOWN LEGS TOWARD PANEL, TYP CROSS TEE RGHC PANEL HOLD DOWN CLIP PERIMETER ANGLE FIELD FASTENER 90° ACA CLIP FIELD FASTENER RG2-WAY CLIP RG HANGER CLIP RGHC - HOLD DOWN CLIP RG-15-MT RG-15-48 RG-15-24 RG-WA-48 RG-WA-24 BEND TABS TOWARDS SQUARE HOLES, TYP GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746

GS080 11.22 G R E E N B Y D E S I GN 1 LEED is a registered trademark of the U.S. Green Building Council. GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746 5023 HAZEL JONES RD. BOSSIER CITY, LA 71111 800.747.8954 GORDON-INC.COM SALES@GORDON-INC.COM • Products contribute to LEED®1 certification • In-House Finishes º Biodegradable pre-treatment (No phosphates) º No hazardous waste º No VOCs º No heavy metals • Reference our sustainability page for more information.

RkJQdWJsaXNoZXIy NDExNjIx