CEILING SUSPENSION

ENVIRONMENTAL GRID

Environmental Grid False Ceiling

Gordon offers a variety of environmental grid systems. Our snap-tab system is provided for ease of installation, while the clip system is available to meet seismic requirements. Special punching for any module is available upon request. All profiles and systems are offered in standard acrylic "wet" in smooth or textured finishes, satin anodized, and custom finishes. 360° paint finish is available for open plenum and perimeter applications. Special fabrication for any module is available upon request.

Main Tees
MT-7 Heavy DWG | DXF | PDF | RFA MT-6 Intermediate DWG | DXF | PDF | RFA MT-5 Intermediate DWG | DXF | PDF | RFA
Environmental Grid MT-7 Environmental Grid MT-6 Environmental Grid MT-5
Cross Tees
CT-7 DWG | DXF | PDF CT-6 DWG | DXF | PDF CT-5 DWG | DXF | PDF
Environmental Grid CT-7 Environmental Grid CT-6 Environmental Grid CT-5
Wall Angles
WA-20 DWG | DXF | PDF | RFA WA-5 DWG | DXF | PDF | RFA
Environmental Grid Wall Angel WA-20 Environmental Grid Wall Angel WA-5
WA-2 DWG | DXF | PDF | RFA WA-1 DWG | DXF | PDF | RFA
Environmental Grid Wall Angel WA-2 Environmental Grid Wall Angel WA-1
Wall Moldings
WS-1010 DWG | DXF | PDF | RFA WA-3-75 DWG | DXF | PDF | RFA
Environmental Grid Wall Angel WS-1010 Environmental Grid Wall Angel WA-3-75
WA-3-50 DWG | DXF | PDF | RFA WA-114 DWG | DXF | PDF | RFA
Environmental Grid Wall Angel Wa-3-50 Environmental Grid Wall Angel WA-114
Snap Tab Assembly DWG | DXF | PDF
Environmental Grid Snap Tab Assembly
Seismic Clip Assembly DWG | DXF | PDF
Environmental Grid Seismic Clip Assembly
Load and Span Table
Type
Depth
Span Hanger Wire Spacing
Spacing of Main Tees
Applied Load
(lbs. per sq. ft.)
MT-7
CT-7
2"
48"

60"

72"

24"
48"
24"
48"
24
48
9.3
4.6
4.7
2.3
2.7
1.3
MT-6
CT-6
MT-5
CT-5
1-1/2"
48"

60"
24"
48"
24"
48"
4.5
2.2
2.3
1.1