LR CLEANROOM GRIDS

LIGHT DUTY, GASKETED CEILING SYSTEMS

Cleanroom 1.5 Inch Ceiling Grid Ceiling

Gordon Cleanroom products LR-15 ceiling system is designed primarily for use in pharmaceutical, hospital and food service cleanroom applications. Extruded aluminum grid members have a ¼” upturned flange to provide a cleanable edge that also conceals the gasket. Blank panels, filters or other ceiling components first contact the gasket to create an airtight seal prior to settling on the tee flange. Grid components are fabricated of extruded aluminum for maximum structural integrity and corrosion resistance, even in harsh environments. Aluminum assembly clips simplify installation and require no special tools to attach grid components. Optional hold-down clips are available to secure blank panels in the grid.

TECHNICAL INFORMATION
Cleanroom 1.5 Inch Ceiling Grid LR Intersection Example
  • EXTRUDED GRID COMPONENTS
    • 6063 T-5 aluminum alloy
  • FINISHES
    • Clear satin anodized for harsh environments
    • White, water-based acrylic "wet coat" paint finish
  • FACTORY APPLIED GASKETS
    • Closed-cell PVC, 8# density
    • U.S.D.A. approved
    • Fungus-resistant (Method 508.1 Mil Std 810-C)
    • Flame-resistant (FMYSS #302; burn rate 4" per minute)
    • Color: Light grey
    • Contact factory for custom gasket availability
  • GRID LAYOUT MODULES
    • 2' x 4'
    • 2' x 2'
    • Metric or custom module sizes can be provided
  • LR APPLICATION GUIDELINES
  • Appropriate for cleanrooms designed to:
    • ISO-7 (Class 10,000) or higher
    • Use ducted terminal filter modules
    • Use cleanroom standard size filters and light fixtures
  • SUSPENSION AND LOAD DATA
    • Minimum 12 gauge hanger wire (furnished by others)
    • Hanger Wire Spacing:
      • 4' o.c. for panels up to 5 lbs. per square foot
      • At all 4 corners of filter module and light fixture location
    • Load test recommendations: See Table
    • NOTE: Gordon does not recommend grid systems for use with fan powered modules (FFU's). Consider Gordon rod-suspended grid systems for FFU applications.
LR PARTS
PART
NUMBER
DESCRIPTION
Cleanroom 1.5 Grid
A-
WEB
DEPTH
B-
EXPOSED
GASKETED
FLANGE
PART
LENGTH
PIECES
PER
CARTON
LINEAL
FEET
PER
CARTON
LBS
PER
CARTON
WEIGHT
PER
LINEAR
FOOT/W
GASKET
LR-15
LR-15-MT4 Main Tee,
Notched 48" o.c.
1-1/2" 1-1/2" 12' 16 192 55 0.31
LR-15-MT2 Main Tee,
Notched 24" o.c.
1-1/2" 1-1/2" 12' 16 192 55 0.31
LR-15-48CN 4' Cross Tee,
Notched 24" o.c.
1-1/2" 1-1/2" 4' 48 192 54 0.31
LR-15-48NN 4' Cross Tee,
No Notch
1-1/2" 1-1/2" 4' 48 192 54 0.31
LR-15-24 2' Cross Tee 1-1/2" 1-1/2" 2' 48 96 27 0.31
WALL ANGLES
LR-WA-48 Wall Angle,
Notched 48" o.c.
1-1/2" 3/4" 12' 24 288 54 0.23
LR-WA-24 Wall Angle,
Notched 24" o.c.
1-1/2" 3/4" 12' 24 288 54 0.23
CLIPS
MTS Main Tee Splice Clip One Per Main Tee 0.02
LR-2 WAY 2-Way Clip One Per LG Cross Tee 0.01
LR-1 WAY 1-Way Clip As Required 0.01
LRHC Panel Hold-down Clip As Required 0.01
LRHGR LR Hanger Clip As Required 0.01
LR COMPONENTS & ACCESSORIES
Cleanroom 1.5 Inch Ceiling Grid LR Components and Accessories Details
LR LOAD DATA

Load test recommendations outlined in the table at right should not be exceeded, nor should the components be deflected more than 1/360th of their span.

A minimum of 12 gauge hanger wire should support all four corners of the filter unit or light fixture.

SYSTEM
TYPE
WEB
HEIGHT
SPAN HANGER
WIRE SPACING
SPACING OF
MAIN TEES
APPLIED LOAD
LBS. / SQ.FT.
LR-15 1-3/4"" 48"
24"
48"
8.9
4.4
GREEN BY DESIGN
  • LEED® 1 credits available
  • 45.3% recycled aluminum
    • 36.9% pre-consumer content
    •   8.4% post consumer content
  • Finishes
    • No hazardous waste
    • No VIC's
    • No heavy metals

1 LEED® is a registered trademark of the U.S. Green Building Council.