Cel•Line®

CL010 02.20 • In-House Finishes • Biodegradable pre-treatment (No phosphates) • No hazardous waste • No VOCs • No heavy metals • Reference our sustainable products brochure and website for more information. Recycled content values are subject to change. Contact us for accurate values or job specific requirements. 2 LEED is a registered trademark of the U.S. Green Building Council. G R E E N B Y D E S I GN • LEED ®2 credits available • 57% - 87% recycled steel coil • 7% - 14% pre-consumer content • 50% - 73% post consumer content • 96% recycled aluminum coil • 48% pre-consumer content • 48% post consumer content 4" X 3" X 2" MAIN CHANNEL CEILING ANCHOR (BY OTHERS) CLASS A POLYETHYLENEWRAPPED ACOUSTICAL INSULATIONTYP (WHERE PERFORATED PANELS ARE USED) MAIN CHANNEL HANGER CLIPTYP *14GA Z-HOLD DOWNTYP 3/8" X 1-1/4" NUT, BOLT & LOCK WASHER TYP (BY OTHERS) 1-1/2" X 1-1/2" X 14GA HANGER ANGLE AT 5'-0" ON CENTER FIELD CUT 6"TO 12" LONG CLIP ANGLE FROM HANGER ANGLE Cel•Line PANELTYP SECTION AT MAIN CHANNEL - CONCEALED STITCHING SCREW (BY OTHERS) SPRING CLIP *14GA Z-HOLD DOWN 2" X 3" X 1" PERIMETER CHANNEL Cel•Line PANELTYP CLASS A POLYETHYLENE WRAPPED ACOUSTICAL INSULATIONTYP (WHERE PERFORATED PANELS ARE USED) WALL ANCHOR (BY OTHERS) CMUWALL CONCEALED LAST PANEL CMUWALL WALL ANCHOR (BY OTHERS) 2" X 2" PERIMETER ANGLE Cel•Line PANELTYP #12 X 3/4"TORX SECURITY SCREWS 6" ON CENTER CLASS A POLYETHYLENE WRAPPED ACOUSTICAL INSULATIONTYP (WHERE PERFORATED PANELS ARE USED) STITCHING SCREW (BY OTHERS) EXPOSED LAST PANEL CLASS A POLYETHYLENEWRAPPED ACOUSTICAL INSULATIONTYP (WHERE PERFORATED PANELS ARE USED) #12 X 3/4"TORX SECURITY SCREWS 6" ON CENTER TYP Cel•Line PANELTYP 3/8" X 1-1/4" NUT, BOLT & LOCK WASHER TYP (BY OTHERS) 1-1/2" X 1-1/2" X 14GA HANGER ANGLE AT 5'-0" ON CENTER FIELD CUT 6"TO 12" LONG CLIP ANGLE FROM HANGER ANGLE CEILING ANCHOR (BY OTHERS) 4" X 4" MAINTEE SECTION AT MAIN CHANNEL - EXPOSED Cel•Line PANELTYP STITCHING SCREW TYP (BY OTHERS) CLASS A POLYETHYLENEWRAPPED ACOUSTICAL INSULATIONTYP (WHERE PERFORATED PANELS ARE USED) 12", 18", OR 24"TYP SECTION - CONCEALED & EXPOSED 2" X 2" PERIMETER ANGLE Cel•Line PANELTYP #12 X 3/4"TORX SECURITY SCREWS 6" ON CENTER CLASS A POLYETHYLENEWRAPPED ACOUSTICAL INSULATIONTYP (WHERE PERFORATED PANELS ARE USED) STITCHING SCREW (BY OTHERS) WALL ANCHOR (BY OTHERS) CMUWALL EXPOSED START PANEL *PATENT PENDING #60/690,427 GORDON - I NC .COM 80 0 . 747. 895 4 FA X 80 0 . 87 7. 8746 5023 HAZEL JONES RD. BOSSIER CITY, LA 71111 800.747.8954 GORDON-INC.COM SALES@GORDON-INC.COM

RkJQdWJsaXNoZXIy NDExNjIx